This manual delivers detailed instructions for the Watson-Marlow Qdos 60 pump‚ ensuring optimal performance through installation‚ operation‚ and troubleshooting guidance.

It highlights precise chemical metering and robust durability‚ making it suitable for demanding water treatment and diverse industrial applications.

The Watson-Marlow Qdos 60 is a peristaltic pump engineered for precise and reliable chemical metering. This manual serves as a comprehensive resource for understanding its capabilities and ensuring safe‚ efficient operation. Designed for a wide range of applications‚ including water treatment‚ chemical processing‚ and laboratory use‚ the Qdos 60 excels in delivering consistent flow rates‚ even with challenging fluids.

Key to its functionality is the use of ReNu peristaltic pump heads‚ offering excellent chemical compatibility and minimal maintenance. The Qdos range‚ including the Qdos 60‚ is known for its durability and suitability for harsh environments. This introduction will prepare you for successful installation‚ operation‚ and maintenance of your pump.

Key Features and Benefits

The Watson-Marlow Qdos 60 boasts several key features delivering significant benefits. Its precise chemical metering capabilities ensure accurate fluid delivery‚ crucial for process control. The pump’s robust design and ReNu pump head options provide excellent chemical compatibility and long-lasting performance‚ minimizing downtime and maintenance.

Furthermore‚ the Qdos 60 offers versatile control options‚ including manual‚ remote‚ and universal relay functionality‚ adapting to diverse application needs. Its ability to handle a wide range of flow rates and pressures makes it suitable for various processes. The pump’s reliability and durability contribute to increased efficiency and reduced operational costs.

Safety Precautions

Prior to operating the Watson-Marlow Qdos 60‚ carefully review all safety guidelines. Qdos drives are not ATEX rated; therefore‚ avoid use in explosive atmospheres. Always disconnect electrical power before performing any maintenance or inspection. Ensure proper grounding to prevent electrical shock.

Wear appropriate personal protective equipment (PPE)‚ including eye protection and gloves‚ when handling chemicals. Avoid contact with moving parts during operation. Never operate the pump against a closed discharge line. Adhere to all local safety regulations and guidelines; Improper use can lead to equipment damage or personal injury.

Unpacking and Inspection

Upon receiving your Watson-Marlow Qdos 60‚ carefully inspect the packaging for any signs of damage during transit. Once opened‚ verify that all components listed on the packing slip are present. This includes the pump drive‚ pump head (Qdos‚ ReNu‚ or CWT)‚ tubing (if applicable)‚ power cable‚ and this manual.

Thoroughly examine the pump drive and head for any visible defects or damage. If any discrepancies or damage are found‚ immediately contact Watson-Marlow Limited and the carrier. Do not attempt to operate a damaged unit. Retain all packaging materials for potential return or inspection.

Installation Procedures

Proper installation is crucial for optimal Qdos 60 performance. This section details mounting‚ tubing connections‚ and electrical setup for safe operation.

Mounting the Qdos 60

Secure mounting of the Qdos 60 pump is essential for stable operation and to prevent vibrations that could affect accuracy. Choose a firm‚ level surface capable of supporting the pump’s weight‚ considering potential fluid loads;

Ensure adequate space around the pump for tubing connections and maintenance access. The pump can be mounted in various orientations‚ but avoid positions that might cause fluid ingress into the drive unit.

Utilize the provided mounting feet and appropriate fasteners for your surface. Verify the mounting is rigid and free from excessive movement before proceeding with tubing installation and electrical connections.

Tubing Selection and Installation

Proper tubing selection is critical for Qdos 60 performance and chemical compatibility. Watson-Marlow offers a range of tubing materials like ReNu and Marprene‚ each suited for specific applications. Consult the chemical compatibility chart to ensure the tubing resists the pumped fluid.

During installation‚ ensure the tubing is correctly loaded onto the pump head‚ following the designated path. Avoid kinks‚ twists‚ or excessive tension. Proper tubing installation minimizes wear‚ maximizes pump life‚ and maintains accurate flow rates.

Regularly inspect tubing for signs of degradation or damage‚ replacing it as needed.

Electrical Connections

Before making electrical connections‚ ALWAYS disconnect power to the Qdos 60. Verify the pump’s voltage and frequency match your power supply. Incorrect connections can cause damage. Connect the pump to a properly grounded electrical outlet‚ adhering to local and national electrical codes.

The pump features a designated cable gland for secure cable entry. Ensure the cable is adequately secured to prevent strain on the connections. Double-check all wiring before restoring power. Qdos drives are NOT ATEX rated and should not be used in explosive atmospheres.

Operational Guidelines

Proper operation involves initial startup‚ careful priming‚ and precise flow rate calibration for optimal performance of the Watson-Marlow Qdos 60 pump.

Initial Startup and Priming

Before initial startup‚ verify all tubing connections are secure and correctly installed‚ referencing the tubing selection guide. Ensure the pump head is properly mounted and the selected tubing is compatible with the fluid being pumped.

To prime the Qdos 60‚ slowly initiate the pump at a low speed‚ allowing the fluid to draw through the tubing. Monitor for any leaks or air bubbles. Continue priming until a consistent‚ bubble-free flow is established.

Avoid running the pump dry for extended periods‚ as this can damage the tubing. Refer to the maintenance section for guidance on tubing replacement.

Flow Rate Calibration

Accurate flow rate calibration is crucial for precise chemical metering. Begin by collecting a known volume of fluid discharged from the pump over a measured time interval. Utilize calibrated measuring equipment for optimal accuracy.

Compare the measured flow rate to the pump’s programmed setting. Adjust the pump’s control parameters as needed to achieve the desired flow rate. Repeat this process several times to ensure consistency and reliability.

Remember that flow rates can be affected by fluid viscosity‚ temperature‚ and tubing condition. Regularly recalibrate the pump to maintain optimal performance.

Control Panel Overview

The Qdos 60 control panel features an intuitive interface for easy operation. The display provides real-time information on flow rate‚ speed‚ and operational status. Use the keypad to program desired flow rates‚ select operating modes (manual‚ remote)‚ and access calibration functions.

The panel also incorporates safety features‚ including alarms for low tubing pressure or pump head errors. Universal Relay functionality allows for external control and integration with other systems. Explore the menu options to customize settings and optimize pump performance for your specific application.

Maintenance and Troubleshooting

Routine maintenance and prompt troubleshooting are vital for sustained Qdos 60 performance. This section details schedules and solutions for common operational issues.

Routine Maintenance Schedule

Regular maintenance ensures the Watson-Marlow Qdos 60 pump operates reliably and efficiently. A preventative schedule minimizes downtime and extends component lifespan. Weekly checks should include visual inspection for leaks‚ tubing wear‚ and proper mounting security.

Monthly tasks involve verifying electrical connections and cleaning the pump housing. Every six months‚ inspect the pump head for any signs of corrosion or damage. Annual maintenance requires a thorough review of all components‚ including tubing replacement as needed‚ and calibration verification to maintain accurate flow rates.

Adhering to this schedule guarantees optimal performance and longevity of your Qdos 60 pump.

Common Troubleshooting Issues

Addressing issues promptly maintains the Watson-Marlow Qdos 60 pump’s performance. Loss of prime often indicates air leaks in the tubing or connections – check for tightness and damage; Reduced flow rate can stem from worn tubing‚ blockages‚ or incorrect calibration; inspect and replace as needed;

Erratic flow may signal electrical interference or a faulty control signal. Pump head issues‚ like excessive wear‚ require immediate attention. Remember‚ Qdos drives are not ATEX rated and shouldn’t be used in explosive atmospheres. Always consult the manual for detailed diagnostics and safety precautions before attempting repairs.

Replacing the Pump Head

Pump head replacement on the Watson-Marlow Qdos 60 requires careful attention. First‚ disconnect power and relieve any system pressure. Remove the existing pump head‚ noting the tubing routing for reinstallation. Ensure the new head’s ReNu or CWT components are correctly aligned.

Securely mount the new head‚ verifying proper seating and tightening of fasteners. Reconnect the tubing‚ ensuring a snug fit to prevent leaks. Finally‚ prime the pump and calibrate the flow rate. Watson-Marlow recommends using genuine spare parts for optimal performance and longevity.

Technical Specifications

The Qdos 60 offers varied flow rates and pressure capabilities‚ utilizing diverse pump head materials like Marprene and Bioprene‚ with specific electrical requirements.

Pump Head Materials

The Watson-Marlow Qdos 60 pump utilizes a range of pump head materials designed for compatibility with diverse fluid handling applications. ReNu pump heads employ peristaltic tubing internally‚ offering excellent chemical resistance and minimal fluid contact. These are ideal for sensitive processes.

Furthermore‚ CWT pump heads feature an element within the head‚ providing enhanced performance with viscous fluids. Materials like Marprene and Bioprene are commonly used‚ selected for their durability and resistance to specific chemicals. Choosing the correct material ensures longevity and prevents contamination‚ optimizing pump performance and maintaining fluid integrity.

Flow Rate and Pressure Capabilities

The Watson-Marlow Qdos 60 pump delivers precise and repeatable flow rates‚ crucial for accurate chemical metering. Flow rates‚ tested with water at 20°C (68°F) with zero suction and delivery heads‚ vary depending on tubing selection and pump speed. The Qdos 60 is capable of handling a broad spectrum of pressures‚ accommodating diverse application requirements.

While specific pressure capabilities depend on the tubing used‚ the pump is engineered for robust performance. It’s important to note that Qdos drives are not ATEX rated and should not be utilized in explosive atmospheres‚ ensuring safe operation within designated environments.

Electrical Requirements

The Watson-Marlow Qdos 60 pump requires careful attention to electrical specifications for safe and reliable operation. Ensure the supply voltage matches the pump’s rating‚ typically available in various configurations to suit regional standards. Proper grounding is essential to prevent electrical hazards and maintain system stability.

Always consult the pump’s nameplate for precise electrical requirements before connecting to a power source. Qdos drives are not ATEX rated‚ restricting their use in potentially explosive environments. Adherence to these guidelines guarantees optimal performance and longevity of the Qdos 60 pump.

Communication Protocols

The Qdos 60 supports remote control via Manual‚ Remote‚ Universal‚ and Profibus options‚ alongside Universal Relay functionality for seamless integration.

Remote Control Options

The Watson-Marlow Qdos 60 pump offers versatile remote control capabilities‚ enhancing operational flexibility and integration within broader process control systems. Users can implement remote operation through various interfaces‚ including manual control for direct oversight and adjustments. Furthermore‚ the pump supports universal communication protocols‚ enabling integration with existing plant automation infrastructure.

This allows for centralized monitoring and control of the Qdos 60‚ streamlining workflows and improving process efficiency. The availability of these options ensures compatibility with diverse control architectures‚ providing a tailored solution for specific application requirements. Remote access facilitates convenient adjustments and data acquisition‚ optimizing performance and minimizing downtime.

Profibus Integration

The Watson-Marlow Qdos 60 pump facilitates seamless integration into Profibus networks‚ a widely adopted industrial communication standard. This capability enables direct communication between the pump and a Profibus master controller‚ allowing for comprehensive process monitoring and control. Through Profibus‚ users can remotely adjust flow rates‚ monitor pump status‚ and receive diagnostic information in real-time.

This integration streamlines automation processes‚ enhancing data accuracy and reducing the need for manual intervention. The Qdos 60’s Profibus interface supports efficient data exchange‚ contributing to improved system reliability and optimized performance within complex industrial environments. Configuration is straightforward‚ ensuring quick and easy network connectivity.

Universal Relay Functionality

The Watson-Marlow Qdos 60 pump incorporates universal relay functionality‚ providing versatile control and signaling options. These relays can be configured for various purposes‚ including flow rate control‚ alarm indication‚ and remote start/stop commands. This flexibility allows seamless integration with existing control systems and simplifies automation processes.

Users can customize relay behavior to suit specific application requirements‚ enhancing system responsiveness and efficiency. The universal relay outputs offer a robust and reliable interface for connecting to PLCs‚ SCADA systems‚ and other external devices. This feature contributes to improved process control and enhanced operational safety.

Warranty Information

Watson-Marlow provides coverage details‚ alongside limitations and exclusions‚ ensuring pump reliability. Refer to the full warranty statement for comprehensive terms and conditions.

Coverage Details

Watson-Marlow’s warranty for the Qdos 60 pump covers defects in materials and workmanship under normal use for a specified period from the date of purchase. This warranty encompasses repair or replacement of defective parts‚ at Watson-Marlow’s discretion. The duration of coverage varies based on the specific components and regional regulations.

The warranty is valid only if the pump is installed and operated according to the guidelines outlined in this manual. Any modifications or unauthorized repairs will void the warranty. Proof of purchase is required to validate any warranty claim. Contact Watson-Marlow directly to initiate a claim.

Limitations and Exclusions

Watson-Marlow’s warranty for the Qdos 60 pump excludes coverage for damage resulting from misuse‚ abuse‚ negligence‚ accidents‚ or unauthorized modifications. Wear and tear of consumable parts‚ such as tubing‚ are not covered. Damage caused by improper chemical compatibility or operating outside specified parameters is also excluded.

Furthermore‚ the warranty does not extend to costs associated with labor‚ shipping‚ or any consequential damages. Use of the Qdos drive in explosive atmospheres‚ as it is not ATEX rated‚ voids all warranty claims. This warranty is the sole and exclusive remedy.

Appendix

This section includes essential Qdos 60 resources: dimensional drawings for installation planning‚ a comprehensive spare parts list‚ and Watson-Marlow contact information.

Dimensional Drawings

Detailed dimensional drawings are crucial for successful Qdos 60 integration into existing systems or new installations. These drawings provide precise measurements of the pump’s footprint‚ including mounting hole locations‚ tubing connection points‚ and overall height and width.

Users should carefully review these diagrams to ensure adequate clearance for maintenance access and to verify compatibility with surrounding equipment. Accurate spatial planning minimizes potential installation issues and ensures optimal pump performance. Watson-Marlow provides these drawings to facilitate seamless integration and long-term operational efficiency.

Spare Parts List

Maintaining a readily available stock of Qdos 60 spare parts minimizes downtime and ensures continuous operation. This list includes essential components such as pump heads‚ tubing‚ valves‚ seals‚ and O-rings. Watson-Marlow recommends keeping critical wear items on hand for quick replacement during routine maintenance or unexpected failures.

Referencing the part numbers provided in this list when ordering ensures compatibility and avoids delays. Regularly inspecting and replacing worn parts extends the pump’s lifespan and maintains optimal performance. Contacting Watson-Marlow directly guarantees genuine parts and expert support.

Contact Information for Watson-Marlow

For technical support‚ spare parts inquiries‚ or general assistance regarding your Qdos 60 pump‚ please reach out to Watson-Marlow directly. Their dedicated team of experts is available to address your questions and provide prompt solutions. You can contact them via phone‚ email‚ or through their official website.