The Xantrex Freedom X 2000 is a powerful and versatile inverter/charger designed for a wide range of off-grid and mobile power applications. It seamlessly combines a pure sine wave inverter, a multi-stage battery charger, and an automatic transfer switch into a single, compact unit.

This robust system provides reliable AC power from DC battery sources, making it ideal for recreational vehicles, boats, emergency backup systems, and remote homes. The Freedom X 2000 excels at handling demanding loads, including appliances, electronics, and power tools.

Understanding its features and proper operation is crucial for optimal performance and longevity. This manual will guide you through every aspect, from initial setup to advanced configuration, ensuring you harness the full potential of your Xantrex Freedom X 2000.

What’s Included in the Manual?

This comprehensive manual provides detailed instructions covering all facets of the Xantrex Freedom X 2000 inverter/charger. You’ll find step-by-step guidance on safe installation procedures, including crucial wiring diagrams and grounding techniques.

We’ve included a thorough explanation of the system’s components – the inverter, charger, and transfer switch – and how they interact. Operational procedures, from power-up to shutdown, are clearly outlined, alongside a detailed breakdown of the control panel’s functions.

Furthermore, this guide offers robust troubleshooting advice for common issues, explanations of error codes, and instructions for accessing advanced features. Finally, resources for maintenance, care, and contacting Xantrex support are readily available within these pages.

Understanding the System Components

The Freedom X 2000 integrates an inverter, charger, and transfer switch, working seamlessly to convert and manage power for reliable performance.

Inverter Section Overview

The inverter is the heart of the Xantrex Freedom X 2000, responsible for converting DC battery power into usable AC power for your appliances and devices. This unit employs a pure sine wave inverter technology, delivering clean, reliable power comparable to utility-supplied electricity. This is crucial for sensitive electronics, ensuring optimal performance and preventing damage.

The inverter’s output power is rated at 2000 watts continuous, with a surge capacity to handle momentary high-demand loads like motor starts. It automatically detects the presence of AC power and switches to inverter mode when AC is unavailable, providing uninterrupted power. Understanding the inverter’s specifications and limitations is key to efficient system operation and preventing overloads.

Charger Section Overview

The Xantrex Freedom X 2000 incorporates a sophisticated multi-stage battery charger designed to efficiently and safely recharge your batteries when an AC power source is available. This charger utilizes a three-stage charging process – Bulk, Absorption, and Float – optimizing battery life and performance. The Bulk stage rapidly replenishes the battery, while Absorption fine-tunes the charge, and Float maintains a full charge without overcharging.

The charger is capable of delivering up to 60 amps of charging current, significantly reducing recharge times. It automatically adjusts the charging parameters based on battery type (flooded, AGM, gel), ensuring compatibility and optimal charging. Proper charger configuration is vital for maximizing battery lifespan and maintaining system reliability.

Transfer Switch Functionality

The Xantrex Freedom X 2000’s transfer switch intelligently manages power flow between AC input sources (shore power, generator) and the inverter output. Its primary function is to seamlessly switch between these sources, prioritizing AC input when available and automatically reverting to inverter power during outages. This ensures uninterrupted power to critical loads.

The transfer switch operates with a very fast switching speed, minimizing disruption to sensitive electronics. It features a search mode, periodically checking for the return of AC power and automatically transferring back when detected. Configuration options allow users to prioritize AC sources or set specific voltage windows for transfer. Understanding the transfer switch’s operation is key to a reliable and efficient power system.

Installation & Setup

Proper installation is crucial for optimal performance and safety. This section provides detailed guidance on wiring, grounding, and connecting power sources correctly.

Safety Precautions Before Installation

Before commencing any installation work with the Xantrex Freedom X 2000, prioritize safety. Disconnect all AC and DC power sources to prevent electrical shock.

Always wear appropriate personal protective equipment (PPE), including safety glasses and insulated gloves. Ensure the installation area is well-ventilated, as batteries can release explosive gases.

Verify that all wiring meets the required gauge and complies with local electrical codes. Improper wiring can lead to fire hazards or equipment damage.

Never work alone; have a qualified assistant present in case of emergencies. Double-check all connections before energizing the system.

Read and fully understand all warnings and cautions outlined in this manual before proceeding. Failure to follow these precautions could result in serious injury or death.

Wiring Requirements & Considerations

Proper wiring is crucial for the safe and efficient operation of your Xantrex Freedom X 2000. DC input wiring must be sized appropriately for the maximum current draw, using the provided charts.

Use only stranded copper wire rated for at least 75°C. Avoid using aluminum wire, as it can cause corrosion and loose connections. Keep DC wiring as short as possible to minimize voltage drop.

AC wiring must comply with all local electrical codes and regulations. A dedicated circuit breaker is required for both AC input and output.

Ensure all connections are tight and secure, using appropriate crimping tools and terminals. Incorrectly terminated wires can overheat and create a fire hazard.

Consider using conduit to protect wiring from physical damage and environmental factors.

Grounding Procedures

Correct grounding is paramount for safety and proper functionality of the Xantrex Freedom X 2000. The inverter chassis must be grounded to a known earth ground, typically via a grounding rod or the electrical service panel’s ground bus.

Use a minimum of 10 AWG copper wire for the grounding connection. Ensure the grounding wire is as short and direct as possible to minimize impedance.

Do not use gas pipes or water pipes as grounding points, as these can be unreliable and pose a safety hazard.

Verify the grounding connection with a multimeter to ensure a low-resistance path to ground.

Improper grounding can lead to electric shock, equipment damage, and interference with other electronic devices. Always consult a qualified electrician if you are unsure about grounding procedures.

Connecting to AC and DC Sources

Before connecting any power sources, ensure the Xantrex Freedom X 2000 is properly grounded, as detailed in the previous section. For AC input, connect to a dedicated circuit breaker of the appropriate amperage, adhering to local electrical codes.

DC connections are made to the battery bank using heavy-gauge cables – size determined by cable length and inverter output.

Always connect the positive (+) DC cable first, followed by the negative (-) cable.

Reverse polarity can cause severe damage to the inverter.

Double-check all connections for tightness and correct polarity before energizing the system.

Use appropriately rated fuses or circuit breakers on both the AC and DC sides for overcurrent protection.

Operating the Xantrex Freedom X 2000

Proper operation involves understanding the control panel, monitoring performance, and following the correct power on/off sequences for optimal functionality and safety.

Power On/Off Procedures

Starting the Xantrex Freedom X 2000 requires a specific sequence to ensure proper system initialization and prevent potential damage. First, verify the DC input voltage is within the acceptable range, typically between 10.5V and 14.4V.

To power on, locate the main power switch – usually on the front panel – and toggle it to the ‘ON’ position. The unit will perform a self-test, indicated by a series of lights and audible beeps. Allow this process to complete fully before connecting any AC loads.

For shutdown, reverse the process. Disconnect AC loads before switching the unit off. Turn the main power switch to ‘OFF’ and allow a brief moment for the system to fully de-energize. This prevents potential surges and ensures longevity.

Avoid frequent cycling of the power switch, as this can reduce the lifespan of internal components.

Understanding the Control Panel

The Xantrex Freedom X 2000’s control panel provides crucial system status information and allows for operational adjustments. The primary display shows input voltage, output voltage, and load percentage. LED indicators signal inverter status (on, fault), charger status (bulk, absorption, float), and transfer switch position (utility, inverter, search).

Several buttons facilitate control. ‘Power’ toggles the inverter on/off. ‘Mode’ cycles through operational modes – inverter, charger, and search. ‘Fault Reset’ clears error conditions after addressing the underlying issue.

A dedicated section displays battery voltage, offering insight into battery state of charge. Familiarize yourself with the meaning of each indicator and button to effectively monitor and manage your power system. Refer to the detailed diagram within this manual for precise component locations;

Monitoring System Performance

Regularly monitoring the Xantrex Freedom X 2000’s performance ensures optimal operation and early detection of potential issues. Pay close attention to the DC input voltage, ensuring it remains within the acceptable range for your battery bank. Observe the AC output voltage to confirm stable power delivery to connected loads.

The load percentage indicator is critical; avoid consistently exceeding 80% to prevent overload situations. Track the charger’s performance, verifying it’s effectively replenishing the battery. Note any unusual noises or smells emanating from the unit.

Utilize the system’s logging capabilities, if available, to record performance data over time. This historical data can be invaluable for troubleshooting and identifying trends. Consistent monitoring promotes longevity and reliability.

Troubleshooting Common Issues

This section provides solutions for frequently encountered problems with the Xantrex Freedom X 2000, aiding in quick diagnosis and effective resolution.

Inverter Not Turning On

If the Xantrex Freedom X 2000 inverter fails to power on, begin by verifying the DC input voltage. Ensure the battery bank is fully charged and connections are secure, checking for corrosion. A low voltage cutoff may be activated.

Next, inspect the DC fuse located near the battery connection; a blown fuse indicates a short circuit or overload. Confirm the remote on/off switch (if installed) is in the ‘on’ position.

Check the AC input; if present, the inverter might be in transfer mode, awaiting utility power stabilization. Finally, examine the inverter’s front panel for any fault indicators or error codes, referencing the manual’s error code section for specific troubleshooting steps. If issues persist, contact technical support.

Charger Not Functioning

When the Xantrex Freedom X 2000’s charger isn’t operating, first confirm AC power is present at the input. Verify the AC breaker hasn’t tripped and the input voltage is within the acceptable range specified in the manual.

Inspect the charger’s DC output voltage; a reading of zero indicates a potential issue with the charging circuitry. Check the charger enable/disable settings on the control panel or through the remote interface.

Examine the charger fuse, typically located near the AC input. A blown fuse suggests an internal fault. Ensure the battery bank isn’t fully charged, as the charger will cease operation when batteries reach full capacity. If problems continue, consult the troubleshooting section or contact support.

Transfer Switch Problems

If the Xantrex Freedom X 2000’s transfer switch malfunctions, power may not seamlessly switch between AC input and inverter output. Initially, verify the AC source is stable and within the acceptable voltage/frequency range. Check the transfer switch delay settings; improper configuration can cause erratic behavior.

Inspect the wiring connections to the transfer switch for looseness or corrosion. A faulty connection can interrupt the transfer process. Listen for unusual clicking or buzzing sounds from the switch itself, indicating a mechanical issue.

Review the error logs on the control panel for specific transfer switch-related codes. If the problem persists, a component failure within the transfer switch may require professional diagnosis and repair.

Overload Protection & Error Codes

The Xantrex Freedom X 2000 incorporates robust overload protection to prevent damage to itself and connected loads. If an overload is detected, the inverter will shut down, displaying a corresponding error code on the control panel. Common codes include “OL1” (mild overload) and “OL2” (severe overload).

Refer to the detailed error code table in the appendix for specific troubleshooting steps. Reducing the load or identifying appliances causing the overload is crucial. Repeated overloads may indicate an undersized inverter for your power needs.

Ensure all connected devices are within the inverter’s continuous and surge power ratings. Ignoring overload warnings can lead to permanent inverter damage and void the warranty.

Advanced Features & Settings

Explore customizable options like Search Mode, remote control functionality, and parameter adjustments to optimize the Xantrex Freedom X 2000 for your specific needs.

Search Mode Configuration

Search Mode allows the Xantrex Freedom X 2000 to automatically seek and utilize available AC power sources. This feature is incredibly useful for situations where AC input is intermittent or unreliable, such as during grid outages or when connected to a generator. Configuring Search Mode involves setting parameters like the search time interval and the acceptable voltage range.

A shorter search interval means the inverter will more frequently check for AC power, potentially reducing transfer times but increasing energy consumption. Conversely, a longer interval conserves energy but may result in a noticeable delay when switching back to AC power. The acceptable voltage range determines how stable the AC source must be before the inverter will switch over. Carefully adjusting these settings ensures optimal performance and prevents unnecessary inverter operation when a suitable AC source is present. Refer to the control panel instructions for detailed configuration steps.

Remote Control Operation

Remote control operation of the Xantrex Freedom X 2000 provides convenient monitoring and control from a distance. Utilizing the optional remote panel (sold separately), users can replicate many of the functions available on the main control panel, including power on/off, mode selection, and system status monitoring.

The remote panel connects to the inverter via a dedicated communication cable. Ensure the cable is securely connected at both ends for reliable operation. The remote display mirrors the inverter’s current state, displaying voltage, current, power levels, and any active error codes. Basic troubleshooting can often be performed remotely, reducing the need to physically access the inverter. Detailed instructions for connecting and operating the remote panel are included in the remote panel’s separate user manual. Always prioritize safety when operating the system remotely.

Customizing System Parameters

The Xantrex Freedom X 2000 allows for customization of several system parameters to optimize performance for specific applications. Access to these settings is typically through the control panel’s advanced menu, requiring a specific access code for security. Key adjustable parameters include low and high voltage disconnect levels, crucial for protecting your battery bank.

You can also configure the charger’s absorption and float voltages to match your battery type (AGM, Flooded, Gel). Search mode sensitivity can be adjusted to balance responsiveness with unwanted transfers. Caution: Incorrect parameter settings can negatively impact system performance or damage components. Always document any changes made and consult the full manual or technical support before altering default settings. Incorrect settings void the warranty.

Maintenance & Care

Regular inspection and cleaning ensure optimal performance and longevity of your Xantrex Freedom X 2000 inverter/charger system; follow these guidelines.

Cleaning and Inspection

Routine cleaning and visual inspections are crucial for maintaining the Xantrex Freedom X 2000’s reliability. Before any inspection, always disconnect both AC and DC power sources to prevent electrical shock.

Use a dry or slightly damp cloth to wipe down the exterior surfaces, removing dust and debris. Do not use abrasive cleaners or solvents, as these can damage the unit’s finish. Pay particular attention to ventilation openings, ensuring they are unobstructed for proper airflow. Inspect all wiring connections for tightness and corrosion; tighten any loose connections and address corrosion promptly.

Check the cooling fan for proper operation. Listen for unusual noises or obstructions. Visually inspect the unit for any signs of damage, such as cracks or loose components. Document any findings and address them accordingly. Regular inspections, performed at least quarterly, will help identify potential issues before they escalate into major problems.

Battery Maintenance Recommendations

The lifespan and performance of your battery bank significantly impact the Xantrex Freedom X 2000’s overall efficiency. Regularly check battery terminals for corrosion; clean with a baking soda and water solution if necessary, then rinse and dry thoroughly. Ensure connections are tight to maintain optimal current flow.

Periodically check the electrolyte levels in flooded lead-acid batteries (if applicable), adding distilled water only when needed. Avoid overfilling. For sealed batteries, verify there are no signs of swelling or leakage. Implement a regular equalization charge cycle (consult your battery manufacturer’s recommendations) to balance cell voltages and prevent sulfation.

Monitor battery voltage regularly, especially during periods of heavy use. Consider using a battery monitor to track state of charge and overall health. Proper battery maintenance extends battery life and ensures reliable power from your Xantrex system.

Long-Term Storage Guidelines

Preparing your Xantrex Freedom X 2000 and battery bank for extended storage is crucial to prevent damage and maintain functionality. Before storage, fully charge the batteries. Disconnect the batteries from the inverter to eliminate parasitic drain. Store batteries in a cool, dry place, avoiding extreme temperatures.

For flooded lead-acid batteries, top off the electrolyte levels with distilled water. Consider using a float charger designed for long-term maintenance to prevent sulfation, but ensure it’s compatible with your battery type. Periodically check battery voltage (every few months) and recharge if it drops below 12.6 volts.

Cover the Xantrex inverter itself to protect it from dust and debris. Review the manual for specific storage recommendations related to the inverter’s components. Proper preparation ensures a quick and easy return to operation when needed.

Resources & Support

Access comprehensive support via the Xantrex website, detailed documentation, and a dedicated technical support team for your Freedom X 2000 inverter.

Xantrex Website & Documentation

The official Xantrex website (xantrex.com) serves as a central hub for all Freedom X 2000 resources. Here, you’ll find downloadable manuals in PDF format, covering installation, operation, and troubleshooting.

Frequently Asked Questions (FAQs) address common user concerns, and a robust knowledge base offers articles and guides on various aspects of the system.

Detailed specification sheets, datasheets, and wiring diagrams are readily available for download. The website also features software updates for the inverter, enhancing performance and adding new features.

Don’t forget to explore the online forums where users share experiences and solutions. Xantrex provides a wealth of self-help materials to empower you with the knowledge to effectively manage your Freedom X 2000.

Contacting Technical Support

If you’ve exhausted the resources available on the Xantrex website and require direct assistance, their technical support team is readily available. You can reach them via phone during business hours; check the website (xantrex.com) for the most current contact number.

Email support is also offered, allowing you to submit detailed inquiries with supporting documentation. Be sure to include your inverter’s model number and serial number for faster service.

Xantrex also provides a support ticket system through their website, enabling you to track the progress of your request.

When contacting support, clearly describe the issue, any error codes displayed, and the steps you’ve already taken to troubleshoot the problem.